Advanced Data Formatting 11 - 5
And the SECOND rule states:
When scanning a Code 128 bar code of length 12, send the first four characters, then send the ENTER
key, then send all remaining data.
If you scan a Code 128 bar code of length 12, the THIRD rule would apply and the SECOND rule would appear to
not function.
Note that using the standard data editing functions also creates ADF rules. Scan options are entered as ADF rules,
and the hierarchy mentioned previously also applies to them. For the Symbol LS9208/LS9208i, this applies to
prefix/suffix programming in the parameter Scan Data Transmission Format.
These rules reside in the same “rule list” as ADF Rules, so the order of their creation is also important.
Default Rules
Every unit has a default rule to send all scan data. Units with custom software may have one or more default rules
burned in. The rules hierarchy checks user programmable rules first, then the default rules. To disable default rules
enter the following general rule in the user programmable buffer:
When receiving scan data, send all data.
Since this rule always applies, ADF never uses the default rules.