48
Model C606Important: To the Operator
150417
PF POWER FAILURE IN HC
A power failure caused the Heat Phase,
Cool Phase, or Total Cycle Time to exceed
the maximum allowed time. If a power failure
occurs, but the heat treatment cycle does
not fail, an asterisk(*) will appear on the third
line of the display.
PS POWER SWITCH OFF
The power switch was placed into the OFF
position during the heat cycle.
TH THERMISTOR FAILURE
A thermistor probe has failed.
OP OPERATOR INTERRUPT
Indicates the heat cycle was aborted in the
OPERATOR INTERRUPT option in the Ser-
vice Menu.
PD PRODUCT DOOR OFF
A product door is not in place or is loose.
The HEAT CYCLE DATA Details record the
temperature in the freezing cylinders and mix
hoppers every five minutes during the heat
treatment cycle. Up to 366 heat treatment cycles are
recorded. The time and temperature is displayed for
the left hopper, left barrel, right hopper, and right
barrel for each phase during the heat treat cycle. An
individual phase or a complete heat treat cycle
containing all four phases can be viewed.
Heat Treatment Phases
HEAT The phase that heats the mix in the
barrels and hoppers to 151°F (66.1°C).
HOLD The phase that maintains the mix
temperature above 151°F (66.1°C) for a
minimum of 30 consecutive minutes.
SOAK The additional heating time that may
follow the HOLD phase to insure the
total HEAT, HOLD, and SOAK time is
not less than 115 minutes.
COOL The phase that refrigerates the mix until
all four temperature zones are cooled
below 41°F (5°C).
In the HEAT CYCLE DATA screen, select the AUTO
symbol to move the arrow up to “Details,” and
then select the Calibration symbol
.
HEAT CYCLE DATA
Standard records
> Details
Exit
Figure 81
The most recent heat treat cycle record (Recd 1) is
displayed with the date and time. Access a different
heat treatment cycle record by selecting the
OPTIONAL FLAVOR symbol
to move the arrow
to “Next record,” and select the Calibration symbol
. Repeat this step until the desired record with the
date and time is displayed.
Recd 1 05/14 00:00
> Display record
Next record
Exit
Figure 82
With the arrow on the Display record line, select the
Calibration symbol
.
HEAT TREAT CYCLE
> HEAT phase temps
HOLD phase temps
SOAK phase temps
Figure 83
Select the OPTIONAL FLAVOR symbol
to scroll
down to the phase to be reviewed. Selecting “ALL
phase temps” will display all four phases of the heat
treat cycle record in sequential order.
HEAT TREAT CYCLE
SOAK phase temps
COOL pha se temps
> ALL phase temps
Figure 84