75
Model C606 Operating Procedures
050112
Step 8
With the pail still beneath the door, remove the
syrup nose fitting from the syrup line fitting by
turning it counter-clockwise. Hold the syrup fittings in
an “up“ position to minimize syrup loss.
(See Figure 179.)
Figure 179
Step 9
Remove the duckbill valve and o-ring from the syrup
nose fitting.
Figure 180
Step 10
Using the white end of the double-ended brush,
scrub the inside of the syrup nose fitting to remove
any residual particles.
Step 11
Using a shake cup filled with an approved 100 PPM
sanitizing solution, rinse the syrup nose fitting
thoroughly.
Step 12
Using a clean, sanitized towel, gently wipe any syrup
from the duckbill valve.
Step 13
Using a shake cup filled with sanitizing solution,
thoroughly rinse the duckbill valve.
Step 14
Install the duckbill valve into the syrup nose fitting
with the flat end aligned with the open slot in the
syrup nose fitting.
Note: Replace the duckbill valve if it is damaged or
extends past the syrup nose fitting slot.
(See Figure 181.)
Figure 181
Step 15
Install the syrup nose fitting onto the syrup line
fitting. Tighten by hand until snug.
Note: The duckbill valve must be wet when the
syrup nose fitting is assembled on the syrup line
fitting. The sanitized water will lubricate the bottom
flat surface and prevent the duckbill from twisting
when the the syrup nose fitting is tightened.
Step 16
Inspect the duckbill valve for proper installation
inside the syrup nose fitting. The tip of the duckbill
valve must be flat to seal the syrup line.
(See Figure 182.)
Figure 182