76
Model C606Operating Procedures
050112
If the tip is not flat, remove the syrup nose fitting and
remove/reinstall the duckbill valve. Using a shake
cup filled with sanitizing solution, rinse the syrup
nose fitting to wet the bottom of the duckbill valve.
Reinstall the syrup nose fitting onto the syrup line
fitting. If the tip will not remain flat when the syrup
fitting is assembled, replace the duckbill valve.
Step 17
Install the o-ring on the syrup nose fitting.
Step 18
Repeat steps 8 through 17 for all syrup flavors.
Step 19
Each syrup flavor must be primed to purge the air
out of the syrup lines. To prime each syrup line, hold
thesyruplineupoveranemptycup.
(See Figure 183.)
Figure 183
Step 20
Touch the CALIBRATION symbol
to display the
menu options. The CALIBRATION symbol
,the
AUTO symbol
on the shake side, and the
OPTIONAL FLAVOR symbol
will be illuminated.
The screen will display the calibration menu options.
(See Figure 184.)
UNFLAVORED DRAW
SYRUP CALIBRATION
SYRUP PRIME
> EXIT
Figure 184
Step 21
Touch the AUTO symbol
or the
OPTIONAL FLAVOR symbol
to scroll the arrow
to SYRUP PRIME. (See Figure 185.)
UNFLAVORED DRAW
SYRUP CALIBRATION
> SYRUP PRIME
EXIT
Figure 185
Step 22
Touch the CALIBRATION symbol to enter the
SYRUP PRIME mode. (See Figure 186.)
SYRUP PRIME
Select a Flavor
< Press to clear
Figure 186
Step 23
Touch the corresponding syrup flavor symbol .
The flavor symbol should be illuminated and the
syrup pump for the selected flavor will start running
at the maximum speed. (See Figure 187.)
Figure 187