The VERIFY CALIBRATION option is used to
verify the amount of syrup dispensed is within
the proper specification. (See Figure 180.)
VERIFY CALIBRATION
Select a Flavor
< Press to Clear
Figure 180
Remove the syrup valve from the dispensing
door. With the line fully primed with syrup,
position the syrup valve over the small
chamber side of the divided syrup cup, then
select the corresponding flavor selection.
Syrup will flow into the cup for 5 seconds (7
seconds for Triple Thick Shake Syrup) then
automatically stop flowing. Place the cup on a
flat surface and check the amount of syrup
dispensed. If the level is not within the correct
specification, the flavor will need to be
recalibrated. (See “Syrup Calibration” on
page 39.)
It is recommended to verify the calibra tion of
each syrup flavor and note any flavors that
need to be recalibrated before exiting the
Manager’s Menu to access the CALIBRATION
Menu.
Select the CALIBRATION symbol
to exit
the VERIFY CALIBRATION screen and return
to the Manager’s Menu list.
The SERVING COUNTER screen is used to
check or reset the number of servings
dispensed from the machine. The SERVING
COUNTER will automatically reset to zero
when the machine is brush cleaned.
(See Figure 181)
SERVINGS COUNTER
LEFT RIGHT
00
> Next
Figure 181
Reset the SERVING COUNTER by selecting
the CALIBRATION symbol
to advance to
the next screen. Select the AUTO symbol
to move the a rrow (>) to YES and select the
CALIBRATION symbol
. The servings
counter will reset to zero and exit back to the
Manager’s Menu. (See Figure 182.)
RESET DRAW COUNTER
YES
>NO
Figure 182
The SET CLOCK option allows the Manager
to adjust the control clock date and time. The
date and time may only be changed after the
freezer has been manually cleaned but before
it has been placed in the AUTO or STANDBY
mode. The following message will be
displayed if the SET CLOCK option is selected
when the machine is not in a brush clean
state. (See Figure 183.)
SET CLOCK
12:01 08/15/2002
NO CHANGES ALLOWED
Press Any Key
Figure 183
To change the date or time, select the SET
CLOCK option in the menu. Touch the AUTO
symbol
to advance the arrow from Exit to
Change, then touch the CALIBRATION
symbol
to select the Change option.
(See Figure 184.)
SET CLOCK
12:01 08/15/2002
Change
>Exit
Figure 184
Downloaded from www.dlmanuals.com