91
Problem Shake Side
Probable Cause
Soft Serve Side
Probable Cause
Either Side
Probable Cause
Corrective Action
The product is
too thick.
Not enough syrup - 1 fl
oz (30 ml) in 5
seconds. For Triple
Thick Shake Syrup: 1
oz (30 ml) ± 1/8 oz (4
ml) in 7 seconds.
Calibrate the syrups. Check that the syrup
containers are not empty.
Freezing cylinder not
primed correctly.
Drain the freezing cylinder and reprime the
machine.
Air/mix pump
incorrectly assembled.
Follow asse mbly procedures carefully.
The viscosity control is
set too cold.
Call an authorized service technician.
Freeze-up in mix inlet
hole.
Call an authorized service technician.
The mix in the
hopper is too
Hopper cover is not in
position.
Clean and sanitize hopper cover and place
in position.
p
p
wa
r
m.
The agitator is not
installed.
Clean and sanitize the agitator and install.
The hopper
temperature is out of
adjustment.
Call an authorized service technician.
The mix in the
hopper is too
cold.
The hopper
temperature is out of
adjustment.
Call an authorized service technician.
Mix Low and
Mix Out probes
are not
functioning.
Milkstone build-up in
the hopper.
Clean hoppers thoroughly.