95
Problem Shake Side
Probable Cause
Soft Serve Side
Probable Cause
Either Side
Probable Cause
Corrective Action
The draw valve
is not closing.
The draw valve was
not aligned with the
actuator bracket when
the freezer door was
installed.
Reassemble with the correct alignment.
Tighten the handscrews in a criss-cross
pattern when installing the freezer door.
The draw valve was
not lubricated.
Lubricate the draw valve and o’rings.
The spinner shaft was
not lubricated.
Lubricate the spinner shaft.
The spinner blade
became disengaged
from the driven spinner
when the draw valve
was raised.
Call an authorized service technician to
check the spinner coupling position on the
motor.
The product is too
thick.
Check that the product temperature is within
specification. (See problem “Product Too
Thick” on page 91.)
The shake actuator
assembly is out of
alignment or is
malfunctioning.
Call an authorized service technician.
The mix pump
will not operate
in the PUMP
mode.
Pump motor is not
running.
Push the pump reset button.
The mix pump
runs constantly
in the AUTO
mode.
Draw valve is not fully
closed.
Raise draw handle so draw valve is closed
all the way.
Downloaded from www.dlmanuals.com