47
Model PH90 Operating Procedures
Step 4
Return to the freezer with a small amount of sanitizing
solution. With a pail below the door spout, dip the door
spout brush into the sanitizing solution and brush clean
the syrup ports in the freezer door, door spout, bottom
of the driven spinner and spinner blade, and syrup line
fittings.
Note: To assure sanitary conditions are maintained,
brush clean each item for a total of 60 seconds,
repeatedly dipping the brush in sanitizing solution.
Figure 81
Step 5
With the syrup port brush, brush each syrup port hole
10 to 15 times. Dip the brush in sanitizing solution
before brushing each port.
Figure 82
Step 6
Fill the squeeze bottle with sanitizing solution. With a
pail beneath the door, insert the adapter end of the
squeeze bottle into the syrup port, and squeeze the
bottle firmly. This action will force solution out of the
adjacent port and down around the spinner. This
procedure should be performed for at least 10 seconds
per port.
Figure 83
Step 7
Install the restrictor cap on the freezer door spout.
Rinse a single service towel (clean, sanitized towel
directly removed from the sanitizer bucket) in
sanitizing solution, and wipe down the freezer door and
area around the bottom of the freezer door . Install the
shake cup holder.
Figure 84