94
83532002 Rev C
8.12.4. Communication Test:
Select a power supply at address 6:
PC: write: ADR 06
Power supply response: “OK”
Command test:
PC write: OUT 1
Power supply response: “OK”
PC write: PV 5.0
Power supply response: “OK”
PC write: PC 10.0
Power supply response: “OK”
Read back the Output voltage test:
PC write: MV?
Power supply response “05.00” (or voltage as seen on the front panel display)
The power supply should turn on and the display will indicate the actual Output voltage
and the actual Output current.