If 99% (Limit two) of the internal memory is full, because of the average input is
higher as the average output, the CaptureModule stops capturing. As soon as
the memory is emptied (less than 10% of capacity), the Capture module will
start capturing again. During this emptying process the CM Flag (Probeflag)
“Capture Module overflow” will be set to “1”. And there is a hint in red text on
the website of the CaptureModule.
If any of the events gets true, stored data is send with maximum bandwidth, so
please activate traffic shaping if needed to avoid data loss (see CHAPTER
4.5.1.2).
4.5.1.7 Filters Table
Figure 4-16: Overview Filters Table
The Filters Table shows an overview about the basic filters (in current picture no filter
shown). These basic filters can be edited by the button Edit Table.
The button Edit Advance Filter opens an editable list of Advance Filter.