37
Port: Please select the port, to which the filter will be applied:
CANA to CANF
Action:
Here you can define, which filter you want to use:
Drop: if you want to drop specific frames
Mark: specific SPY-flag is set in TECMP-header
Change Channel ID: you can change the Channel ID in
TECMP header of specific frames
Control Message: If the filter condition is met then an
additional frame is sent with the field "Control Message ID"
specified in Parameter box.
Multiple Log Interfaces: Here you can define for a specific CAN-ID the logging
port(s) independent from the standard logging port (Output to from CAN-Port).
The CAN-ID is only logged on selected ports.
Parameter: Parameters are used in chosen Action: Control Message. It specifies the
Control Message ID.
And parameters are used in Action: Change Channel ID as value for the new Channel
ID.
Multi Log Interfaces: Only available if Action: Multi Log Interfaces is chosen. Any
combination is possible:
BaseT1: Logging on 100BASE-T1 port
BaseT1: No logging on 100BASE-T1 port
GB_A: Logging on GB-A port
GB_A: No logging on GB-A port
Field:
Here you can define, what you want to filter:
Field: no specific value, it has to be changed
CAN Id: here you can define which CAN_Id the filter has affect to
(XXX [hex], e.g. 12f)
Payload: Here you can define which payload of a CAN-message the filter has
affect to
Value:
Here you define the value of your Field. Allowed values depend on the chosen Field.
How to use Advance Filter:
Please see CHAPTER 4.9