4.5.6 Flexray Port
Figure 4-24: FlexRay Port
Port name: Port name of the FlexRay Port can be changed.
Output to: Here you can define the logging port of the incoming traffic on this port.
None: no logging port defined => no logging possible
100Base-T1: 100Base-T1 is defined as logging port (Not the Host!)
GB-A: GB-A is defined as logging port
Channel ID: It is a hexadecimal number. E.G B0”. It is a number assigned to any port
separately. For further information see definition of TECMP-protocol.
Keep Awake Reason Bus:
This port is supervised. If on this port is communication, CM_CAN_Combo can’t
go asleep.
This port is not supervised. The Capture Module can fall asleep even there is
communication on this port.
Wake Up Source:
If the device is in standby-mode and there is incoming traffic, the device will enter
normal mode. For details see CHAPTER 4.4.3
If the device is in sleep-mode and there is incoming traffic, the device will not enter
normal mode and stay in standby-mode