CM CAN Combo User Manual
44
Bit sample point: Possible values are between 50 and 90 [%]. It is the point when a high
level is measured. A good value is round about 75 (default value)
Channel ID: It is a hexadecimal number. E.G “B0” It is a number assigned to any port
separately. For further information see definition of TECMP-protocol.
Keep Awake Reason Bus:
This port is supervised. If on this port is communication, CM_CAN_Combo can’t
go asleep.
This port is not supervised. The CaptureModule can fall asleep even there is
communication on this port.
Wake Up Source:
If the device is in standby-mode and there is incoming traffic, the device will enter
normal mode. For details see CHAPTER 4.4.3
If the device is in standby-mode and there is incoming traffic, the device will not
enter normal mode and stay in standby-mode.
Time Stamp:
Timestamp is in nano seconds [ns] resolution and with an accuracy of 40 nano
seconds [ns] (starting with epoch time, if no PTP master is connected)
Messages Received: Counter for received messages on this port from the connected
CAN-Bus
Messages with Error: Counter for received messages on this port from the connected
CAN-Bus containing an error. For example, CRC errors.