4.4.5 WUP time to LOW
Figure 4-11: WUP time to LOW
Here you define the time in seconds, which has to go by before the actuator of the
wakeup lines is set to ground. The starting point of timecounter is the same time as
there is no reason anymore to be awake of the CM_ETH_Combo itself.
Default value is 10 seconds.
4.4.6 Sleep Timeout
Figure 4-12: Sleep Timeout
Here you define the time in seconds, which has to go by with no communication on the
supervised ports before the CM_Eth_Combo falls asleep. Reasonable values are
between 15s and 300s.