CM Eth Combo User Manual
40
reply of the device connected to the BASE-T1 port (ARP-Target filter and IPv4
Destination filter). Please, activate the function Working as DLT-port, too.
For further information please see CHAPTER 4.8.
100/1000 BASE-T1 Inputs: This is a table which shows an overview of all BASE-T1-
Ports. And if the logging-configuration of each port is linked to the selected GB-port.
BR-1A” means OABR-1A sends its logged information to this GB-port
BR-1A” means OABR-1A does not send its logged information to this GB-port.
4.5.4 100BASE-T1 Ports
Figure 4-22: 100BASE-T1Port
Port name: Port name of every 100BASE-T1 Port can be changed.
BroadR-Reach® mode: You can change here the Master/Slave Configuration of Host
Port
Output to: Here you can define the logging port of the incoming traffic on this port.
None: no logging port defined => no logging possible
GB-A: GB-A is defined as logging port => logging with this port is possible.
GB-B: GB-A is defined as logging port => logging with this port is possible.
For multiple logging ports please use Advance filter.