Doing: Navigate to rule number by the buttons and ➔ press button ➔
press the button ➔ select the Port BR1B ➔ select the action Drop ➔ select the
open bracket ➔ choose in Field Outer VLAN ➔ press the button ➔ type the Value
“123” and press ENTER ➔ select the close bracket ➔ press the button ➔ select
the open bracket ➔ choose in Field IP-Msg Dest IPv4 ➔ press the button ➔ type
the value 160.48.199.125 and press ENTER ➔ select the close bracket ➔ press the
button ➔ save the changes. ➔ finished
4.8 Inject
If you want to get access to a DUT on the BASE-T1 port by a device on the logging port,
a few preconditions are necessary:
Only one device can inject on one GB Port
For the Inject, the DUT on the BASE-T1 ports has to be connected directly on the
BASE-T1 port, no switches in between.
Traffic can be injected only to one DUT per BASE-T1 port.
The communication between device and DUT has to be an IP-based protocol
like TCP
The following example shows how to configure the CaptureModule for inject:
The test setup of the example is shown in the
FIGURE 4-27:
The PC has the IP 160.48.199.125.
The DUT_2 has the IP 160.48.199.55.
We want to establish a TCP connection
between PC an DUT_2.
The Communication between all devices has
innerVLAN-tag.