CM Eth Combo User Manual
36
Port: Please select the port, to which the filter will be applied
Action:
Here you can define, which filter you want to use:
Drop: if you want to drop specific frames
Mark: specific SPY-flag is set in PLP-header
Log without PLP: not available
Change BusSpecID: you can change the BusSpecID in PLP
header of specific frames
User Event: If the filter condition is met then an additional
frame is sent with the field "user event ID" specified in
Parameter box.
Multiple Log Interfaces: Here you can define for a specific logged data the logging
port(s) independent from the standard logging port (Output to from BASE-T1-Port).
The data is only logged on selected ports.
Parameter: Parameter is used in chosen Action: User Event”. It specifies the
UserEventID.
And it is used in “Action: Change BusSpecID” as value for the new BusSpecID.
Multi Log Interfaces: Only available if Action: Multi Log Interfaces is chosen. Any
combination is possible:
GB_A/B: Logging on this GB-port
GB_A/B: No logging on GB-port
VLAN Format:
If the original logged frame contains a VLAN (inner or outer) the corresponding box
must be checked:
OutVlan: The original logged frame has outerVLAN-tag
OutVlan: The original logged frame has no outerVLAN-tag
InVlan: The original logged frame has innerVLAN-tag
InVlan: The original logged frame has no innerVLAN-tag