CM Eth Combo User Manual
43
Keep Awake Reason Bus:
This port is supervised. If on this port is communication, CM_Eth_Combo can’t go
asleep.
This port is not supervised. The Capture Module can fall asleep even there is
communication on this port.
Section: It is a hexadecimal number. E.G “1A8”
It is a number assigned to any port separately. For further information see definition
of PLP-protocol. This value is used as VLAN-ID for the function Use OuterVlans in
CHAPTER 4.5.1.4.
BusID: It is a hexadecimal number. E.G “B0”
It is a number assigned to this port and the paired port (A is paired with B). For further
information see definition of PLP-protocol.
Enable Injection for this port:
If activate this function, you get access to a device directly connected on this
1000BASE-T1 Port by a GB-Port. After activating please apply the IP-address of the
connected device in the field “IP for Injection.
Note: Don’t forget to set “IP for Injection” on the specific GB-Port.
Note: Don’t forget to configure the field “Maximal delay (bytes) for Injection
No Injection possible on this port
IP for Injection: This field is available if the box Enable Injection for this port is
checked. Please fill in the IP-Address of the device directly connected on this port and
you want to get direct access by the GB-port.
Maximal delay (bytes) for Injection:
This field is available if the box Enable Injection for this port” is checked. Please fill in
a value many times higher than 512. The maximum is 1536 bytes. For higher
performance a small value is recommended.
This value is the maximum size of the possible inject frame, which is sent by the device
connected on the configured “Output to” GB-port.
Time Stamp: Timestamp in nano seconds [ns] resolution and accuracy of 40 nano
seconds [ns]
Messages Received: Counter for received messages on this port from the connected
1000BASE-T1-device
Messages with Error: Counter for received messages on this port from the connected
1000BASE-T1-device containing an error. For example, CRC errors.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technica Engineering IVN2Eth and is the answer not in the manual?

Technica Engineering IVN2Eth Specifications

General IconGeneral
BrandTechnica Engineering
ModelIVN2Eth
CategoryControl Unit
LanguageEnglish

Related product manuals