TP8-96 VIDEO - Installer Manual Programming of access codes and keys
5-5
PROGRAMMING OF THE ATTRIBUTES
To associate the attributes to the key check the relevant item.
z By-pass general alarms
If checked, the user will be entitled to arm the system even
in presence of a general alarm (i.e. tamper, low battery,
power failure, supervision, trouble modules)
z Automatic communicator block on disarming
If checked, upon disarming of the system (by inserting the
key into the key reader) the active telephone channels (and
those queued up) are blocked automatically.
z Confirmation of disarming (hold-up block)
Activates the hold-up function on the key. In this case,
disarming by this key will have to be confirmed by entering of
a valid user code within a determined period of time
(disarming confirmation delay), otherwise a silent hold-up
alarm will be released.
z Zone exclusion disabled
If checked, the user will not be entitled to arm the control
panel excluding some of the zones (both voluntary and
automatic zone exclusion are disabled). The control panel
will be armed in any case, and if there are open zones, the
alarm will be released.
z Quick disarming
On introduction of the electronic key into the key reader,
while the control panel is armed, all the associated programs
are disarmed. In this case the electronic key will arm/disarm
only the first program associated to it.
z Key has been recognized successfully
Indicates if the selected key corresponds to a memorized
one. If the item is checked, the key has been recognized.
Repeat the procedure for all the user codes (1 to 100).
See § 5.4 for explanatory notes.
Press:
z OK to confirm and quit
z Abandon to quit without saving