TP8-96 VIDEO - Installer Manual Programming of time parameters
4-3
4.2 TIMERS
Open the time configuration tables and select Timer window. On the screen is viewed:
The timer configuration table permits:
z Programming of the 16 timers
z Programmation of the test call
z Programmation of the test call server
PROGRAMMING OF THE TIMERS
The following parameters can be set for every timer:
z Frequency of activation
z Hour of activation
z Associated function
z Associated programs (1 to 8) or remote controls (1 to 8)
Frequency of activation
Select the timer to be configured by clicking on the first item from the
left and scroll down the list to select the frequency:
z Not active z Every day
z Every working day z Every holiday-eve
z Every holiday z Every sunday
... z Every saturday
Hour of activation
Select the items hh and mm and enter the hour of activation
requested.
Associated function
Select the function item and scroll down the list to select the function
the timer has to execute:
z arming
z disarming
z by-pass
z activation of remote control
z deactivation of remote control
z Qualified arming (avoid arming in the presence of low battery,
power failure, tamper, supervision, fault and antimasking alarm).