TP8-96 VIDEO - Installer Manual Programming of wireless devices
6-1
6. PROGRAMMING OF WIRELESS DEVICES
Permits programmming of the wireless devices. Clicking on the above icon, on the screen is viewed:
The tables of the wireless device configuration permit:
z Programming of the wireless sirens
z Programming of the wireless consoles
6.1 PROGRAMMING OF THE WIRELESS SIRENS
The control panel manages max. 4 wireless sirens which are individually programmable according to the following
parameters:
z Time parameters (sounding, siren delay, duration flashing light)
z Functioning (volume of sounding, siren mode)
z Activation mode (not active, bell, flashing light, siren+flashing light) for alarm, prealarm, signaling or technical
alarm.
PROGRAMMING OF THE TIME PARAMETERS
To program the time parameters click on the items and enter
the values requested:
z Sounding time (mm:ss)
Determines the sounding time in case of alarm.
z Siren delay (mm:ss)
Determines the interval between the detection of an alarm
and the activation of the siren.
z Flashing time (mm:ss)
Determines the blinking time in case of alarm or technical
alarm.