4-50
Group 18 Slip Compensation Parameters
Code Parameters Setting Range Default Unit
Control mode
Attribute
V/F SLV
PM
SLV
18-00
Slip Compensation Gain at
Low Speed.
0.00~2.50
VF:0.00
- O O X *1
SLV:***
18-01
Slip Compensation Gain at
High Speed.
-1.00~1.00 0.0 - O O X *1
18-02 Slip Compensation Limit 0~250 200 % O X X
18-03
Slip Compensation Filter
Time
0.0~10.0 1.0 s O X X
18-04
Regenerative Slip
Compensation Selection
0:Disable
1:Enable
0 - O X X
18-05 FOC Delay Time 1~1000 100 ms X O X
18-06 FOC Gain 0.00~2.00 0.1 - X O X
***:Refer to the following attachment 1