4-127
Time diagram for 03-17 ≥ 03-18 is shown below.
03- 19 Relay (R1A-R2B) Type
Range
【xxx0b】:R1 A Contact 【xxx1b】:R1 B Contact
【xx0xb】:R2 A Contact 【xx1xb】:R2 B Contact
If 03-19=0, When the set conditions of 03-11,03-12 are met , relay contact is closed.
If 03-19=1, When the set conditions of 03-11,03-12 are met ,relay contact will open.
03- 20 Internal/External Multi-Function Input Terminal Selection
Range
【0~63】
The parameter is decided which terminal will be used. (input or output terminal). If you select
internal terminal, the corresponded point will be set to 1, if the you select external terminal, the
correspond point will be set to 0.
DI S6 S5 S4 S3 S2 S1
Binary
5
2
4
2
3
2
2
2
1
2
0
2
Decimal 32 16 8 4 2 1
Each bit of 03- 20 means:
03- 20= 0
0 0 0 0 0
S6 S5 S4 S3 S2 S1
0:External Multi-function terminal (remote control)
1:Internal Multi-function terminal (based on 03-21)