4-225
Group 22 PM Motor Parameters
22- 00 PM Motor Rated Power
Range
【0.00~600.00】kW
22- 02 PM Motor Rated Current
Range 25%~200% inverter’s rated current
22- 03 PM Motor’s Pole Number
Range 【2~96】Poles
22- 04 PM Motor’s Rated Rotation Speed
Range 【0~60000】RPM
22- 05 PM Motor’s Maximum Rotation Speed
Range 【0~60000】RPM
22- 06 PM Motor Rated Frequency
Range 【4.8~599.0】Hz
The PM parameter group can be restored to factory setting (13-08), please confirm
the motor rating before initializing the inverter (13-00).
PM motor rated power (22-00)
Set the motor power according to the motor nameplate.
PM motor rated current (22-02)
Set the motor full load according to the motor nameplate.
PM motor pole number (22-03).
Set the number of motor poles according to the motor nameplate.
PM motor rated speed (22-04)
Set parameter 22-04 or 22-06, the inverter will automatically calculate the one or the other.
Set the motor rated speed in rpm according to the motor nameplate.
PM motor maximum rotation speed (22-05)
Set the maximum motor rated speed in rpm according to the motor nameplate.
PM motor rated frequency (22-06)
Set the motor rated frequency according to the motor nameplate.
Only needs to set one of PM motor rated speed (22-04) and PM motor rated frequency (22-06),
inverter will calculate another one automatically, refer the formula below: