7-27
Setting description:
Setting Description
0 Not used
1 The TIC function switch is an over-temperature protection signal
2 The SIC function switch is an over-temperature protection signal
Cn010
CCW Direction Torque Command Limit Value
5-2-5
5-3-7
5-4-8
Initial Value Unit Setting Range Effective Cn029 Reset
200 ~ 300
Note)
%
0 ~ 300 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
000BH 200AH 200AH O O O O O
Setting Description: To limit the Torque Command of CCW direction with doubled Rated Torque, set Cn010=200.
Cn011
CW direction torque command limit value
5-2-5
5-3-7
5-4-
8
Initial Value Unit Setting Range Effective Cn029 Reset
-300 ~ -200
Note)
%
-300 ~ 0 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
000CH 200BH 200BH O O O O O
Setting Description: To limit the Torque Command of CW direction with two times the Rated Torque, set Cn011=-200.
Note) Default and setting range of parameter Cn010/Cn011 vary by driver model.
200V
JSDG2S Matching Motor
Cn030 setting value
Torque command limit value
Matching
Capacity
Motor Model Cn010(%) Cn011(%)
10A
JSMA-PSCP5A H101
300 -300
JSMA-PUCP5A H105 300 -300
JSMA-PSC01A H102 300 -300
JSMA-PUC01A H106 300 -300
JSMA-PBC01A H107 300 -300
JSMA-PUC02A H108 240 -240
JSMA-PBC02A H109 240 -240
15A
JSMA-PSC01A H111 300 -300
JSMA-PSC02A H113 300 -300

Table of Contents