7-90
Pn346.0 Full-closed loop function activation
5-6-13
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0337H 232EH 232EH O O -- -- --
Setting Description:
Setting Description
0 Close
1 Activate
Pn346.1 Full-closed loop origin signal source selection
5-6-13
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0337H 232EH 232EH O O -- -- --
Setting Description:
Setting Description
0 Servo motor encoder
1 External encoder
Pn346.2 Full-closed loop function dividing selection
5-6-13
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0337H 232EH 232EH O O -- -- --
Setting Description:
Setting Description
0 Servo motor encoder
1 External encoder