EasyManua.ls Logo

TECO JSDG2S-20A-EL - Page 451

TECO JSDG2S-20A-EL
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-89
Pn341 Low frequency suppression frequency (second set)
6-5
Initial Value Unit Setting Range Effective Cn029 Reset
1000 0.1Hz 10 ~ 1000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0332H 2329H 2329H O O O - -
Setting Description: Used to eliminate the Low Frequency Vibration generated by insufficient mechanism rigidity.
Pn342 Low frequency suppression parameter (second set)
6-5
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 30 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0333H 232AH 232AH O O O - -
Setting Description: Used to adjust the frequency range to be suppressed, greater the value, wider the frequency range of
suppression is, the recommended setting is 10.
Pn343 Low frequency suppression frequency (third set)
6-5
Initial Value Unit Setting Range Effective Cn029 Reset
1000 0.1Hz 10 ~ 1000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0334H 232BH 232BH O O O - -
Setting Description: Used to eliminate the Low Frequency Vibration generated by insufficient mechanism rigidity.
Pn344 Low frequency suppression parameter (third set)
6-5
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 30 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0335H 232CH 232CH O O O - -
Setting Description: Used to adjust the frequency range to be suppressed, greater the value, wider the frequency range of
suppression is, the recommended setting is 10.