7-88
Pn337 Automatic Low Frequency Vibration Suppression Delay
【
6-5
】
Initial Value Unit Setting Range Effective Cn029 Reset
100 1ms 0 ~ 1000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
032EH 2325H 2325H O O O - -
Setting Description: Automatically detects the delay time of low frequency vibration frequency
Pn338 Low Frequency Swinging Detection Level
【
6-5
】
Initial Value Unit Setting Range Effective Cn029 Reset
100 0.1 % 1 ~ 1000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
032FH 2326H 2326H O O O - -
Setting Description: The detection level when executing automatic low frequency vibration suppression (Pn336=1~3), this
value setting method is used to set the percentage of the positioning completion determined value
(Pn307), adjusting the low frequency swinging detection level (Pn338) can adjust the detection
sensitivity, and the lower the setting the easier for the noise to be determined incorrectly.
Pn339 Low frequency suppression frequency (first set)
【
6-5
】
Initial Value Unit Setting Range Effective Cn029 Reset
1000 0.1 Hz 10 ~ 1000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0330H 2327H 2327H O O O - -
Setting Description: Used to eliminate the Low Frequency Vibration generated by insufficient mechanism rigidity.
Pn340 Low frequency suppression parameter (first set)
【
6-5
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 30 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0331H 2328H 2328H O O O - -
Setting Description: Used to adjust the frequency range to be suppressed, greater the value, wider the frequency range of
suppression is, the recommended setting is 10.