8-111
Bit Description Support
0 Ready to switch on O
1 Switch on O
2 Operation enabled O
3 Fault O
4 Voltage enabled O
5 Quick stop O
6 Switch on disable O
7 Warning X
8 Manufacturer specific X
9 Remote O
10 Target reached O
11 Internal limit active X
12 - 13 Operation mode specific O
14 Manufacturer specific X
15 Return to zero completed
O
(for V1.5 & above)
(4) Object 605Ah: Quick stop option code
INDEX 605A
h
Name Quick stop option code
Object Code VAR
Data Type INTEGER 16
Access RW
PDO Mapping No
Value Range 0:Disable drive, motor is free to rotate
1: Slow down on slow down ramp
2: Slow down on quick stop ramp
3: Stop on current limit
4: Stop on voltage limit
5: Stop on voltage limit
6: Stop on voltage limit
7: Stop on current limit
8: Stop on voltage limit
Default Value 0
(5) Object 605Bh: Shutdown option code
INDEX 605Bh
Name Shutdown option code
Object Code VAR
Data Type INTEGER 16
Access RW
PDO Mapping No
Valu e Ran ge
0: Disable drive, motor is free to rotate
1: Slow down on slow down ramp
Default Value 0