P6105 PROBE
SPECIFICATIONS
Electrical:
Attenuation: 10X within 3% (oscilloscope input, 1 Mfi within 2%).
Input Resistance: 10 MSI within 0.5% (oscilloscope input, 1 M!) within 2%).
Approximate Input Capacitance:
1 Meter (3.3 ft)
Blue
2 Meter (6.6 ft)
Yellow
3 Meter (9.9 ft)
Red
SStf 10.5 pF
cs; 13.0 pF ~ 15.5 pF
See Fig. 1 and 2.
Typical parallel reactance (Xp) and
resistance (Fp ) VS.
frequency.
Compensation Range: 15 pF to 47 pF.
Bandwidth (-3 dB) : At least 100 MHz for the 1 and 2 meter, and
at least 95 MHz for the 3 meter.
Maximum Input Voltage: 500 Volts (dc + peak ac), derated with frequency.
See Fig 3, Voltage vs Frequency Derating.
Environmental :
Probe operates within specifications over the following ranges:
Temperature: -15 C (+5 F) to +75 C (+167 F).
Altitude: To 15,000 feet.
Physical:
Net Weight (including accessories) :
1 Meter (3.3 ft) Probe: 105.8 gran
2 Meter (6.6 ft) Probe: 130.4 gran
3 Meter (9.9 ft) Probe: 153.0 gran
(3.7 oz.)
(4.6 oz.)
(5.4 oz.)