Operating Basics
SPG600 & SPG300 Sync Pulse Generators User Manual 2-5
SDI 3 and SDI 4
Serial digital black or serial digital test signal outputs (SPG600 Option 03 only).
By default, the SDI 3 connector outputs a serial digital black signal, and the SDI 4
connector outputs a serial digital test signal. Use the System menu to change the
output channel configuration.
AES 1+2, AES 3+4,
AES 5+6, and AES 7+8
AES/EBU serial digital audio outputs for channels 1 & 2, 3 & 4, 5 & 6, and 7 & 8
respectively (SPG600 only).
1+2/RIGHT and 3+4/LEFT
(XLR connector)
AES/EBU serial digital audio or analog audio outputs for channels 1 & 2 and
3 & 4 respectively. By default, these connectors output an AES/EBS serial digital
audio. Use the System menu to change the output configuration.
WORD CLK
48 kHz word clock signal output.