SDI OUTPUT (STD). Sets the output configuration for the digital serial outputs
(SDI 1 and SDI 2). Use the left (
W) or right (X) arrow button to make the selection.
You can select the following configurations:
BLACK:1 TEST:2: A serial digital black signal is output from the SDI 1
connector, and a serial digital test signal is output from the SDI 2 connector.
BLACK: TEST:1,2: Serial digital test signals are output from the SDI 1 and
SDI 2 connectors.
Press the ENTER button to confirm the selection.
SDI OUTPUT (OPT). Sets the output configuration for the optional digital serial
outputs (SDI 3 and SDI 4). Use the left (
W) or right (X) arrow button to make the
selection. You can select the following configurations:
BLACK:3 TEST:4: A serial digital black signal is output from the SDI 3
connector, and a serial digital test signal is output from the SDI 4 connector.
BLACK: TEST:3,4: Serial digital test signals are output from the SDI 3 and
SDI 4 connectors.
Press the ENTER button to confirm the selection.
XLR OUTPUT. Sets the output configuration for the XLR audio outputs
(1+2/RIGHT and 3+4/LEFT). Use the left (
W) or right (X) arrow button to make
the selection. You can select the following configurations:
AES/EBU Audio: AES/EBU digital audio signals are output from the
1+2/RIGHT and 3+4/LEFT connectors.
Analog Audio: Analog audio signals are output from the 1+2/RIGHT and
3+4/LEFT connectors.
Press the ENTER button to confirm the selection.