Restoration to Service
Refer to “Restoring Engine to Service” on page 197, and “Restoring Transmission to
Service” on page 198, for the procedures required to restore these components to service.
Remove the MACHINE from storage via the following procedure:
1. Remove preservative lubricants from all surfaces.
2. Check all fluid levels, adding or draining as required.
3. Lubricate the machine according to Section 9, making certain that all points
with grease fittings are lubricated.
4. Make a thorough visual inspection of the entire machine, placing special
emphasis on the condition of all hydraulic hoses.
RT500
Maintenance
196 REVISED: