Restoring Transmission to Service
1. If Nox Rust, or equivalent, was used in preparing the transmission for storage,
use the following procedures to restore the unit to service.
2. Remove the tape from openings and breather.
3. Wash off all the external grease with solvent.
4. Add hydraulic transmission fluid, type C3 to proper level.
NOTE: It is not necessary to drain C3 oil and Nox Rust mixture from the
transmission.
5. If Nox Rust or equivalent, was not used in preparing the transmission for
storage, use the following procedures to restore the unit to service.
6. Remove the tape from openings and breathers.
7. Wash off all the external grease with solvent.
8. Drain oil.
9. Install a new oil filter element(s).
10. Refill transmission with hydraulic transmission fluid, type C3 to proper level.