6 Using the product
48
2. Evaluate measurement result: [▲], [▼] → [OK].
- The measurement result is displayed
3. Save measurement result: [Save].
Options
> [Options] → Show Graphic: a section of past measuring
values is displayed in a line graph (zoom function available [▲],
[▼]).
> [Options] → Manometer: The measuring values are displayed
in the same way.
> [Options] → Factory setting: the values are reset to the
default settings.
> [Options] → Overall graphic curve: the measuring values
across the overall measuring time are displayed in a line graph.
6.2.4.5. Caravan Check
The caravan check is a tightness test in accordance with DVGW
G 607 and relates to vehicles with a permanently installed gas
system. The whole gas installation is checked.
Call up function:
> [] → Measurements → [OK] → Gas pipe (TRGI 2008 →
Caravan Check → [OK].
Set parameters
Parameters Explanation
Stability time Set stability time
Measurement period
(nominal)
Set measurement period (nominal)
Diff. pressure ∆pmax
Set maximum permissible differential
pressure
Pressure build-up
Automatic
Pressure is built up automatically via the
integrated pressure pump (up to max.
200 mbar, up to max. line volume 5 l)
Test pressure (nom.) Set test pressure
Vehicle number Enter vehicle number
Inspector Enter inspector's name