To Omit Zones
It is possible to exclude (omit) or include individual zones
during setting i.e. if a zone is ‘in fault’. Users with access to
this function can only omit zones that have been
programmed as ‘Omittable’.
To omit zones when arming, proceed as follows:
Enter a valid User code
....
........
....
, the display
should look like this:
!"#$"%#&'()#)"
*+,#-$-).,/
Press
3
33
3
, the display will look something like this:
F"(.#55 3WA.>% +.
?+"()#! ""+### ##X
Enter the zone number
...
......
...
or use the
)
))
)
key to search, the display will look something like this:
F"(.#53 5W*>)1 R.
T"%(L.# !.).>) "+#X
!
If the zone can be omitted, there will be a ‘Star’ to
the right of the zone number. Only zones that have
the ‘Omit’ attribute assigned to them can be omitted.
Press
3
33
3
to omit the selected zone, the display will look
something like this:
F"(.W53 5W*>)1 R.
1-#D,1)).<
F"(.W53 5WA.>% +.
T"%(L.# !.)>)" +#X
!
A ‘Star will appear to the left of the zone number to
indicate that the zone has been selected for omitting.
Repeat for other zones if required.
When all the required zones have been selected for omitting
press
/
//
/
, the display should look like this:
!"#$"%#&'()#)"
*+,#-$-).,/
Continue to arm the system/area as normal (see page 9 or
11 for details).
The selected zones are now omitted.
!
All omitted zones will be automatically reinstated the
next time the system/area is disarmed, unless
programmed otherwise.
Re-instating Zones Manually
If the system has been programmed for zones to be re-instated
manually, simply follow the instructions again. However, when
the
3
key is pressed, the display will look something like this:
F"(.W53 :#A.>% +.
1-#_")# D,1)). <
F"(.W53 :#A.>% +.
U'>O#!" "+#### ##X
View Zone Status
Users with access to this feature will be able to check the
status of each zone on the system to see whether it is
in ‘Fault’, ‘Secure’, ‘Tamper’ or ‘Shorted’.
To view the status of zones, proceed as follows:
Enter a valid User code
....
........
....
, the display
should look like this:
!"#$"%#&'()#)"
*+,#-$-).,/
Press
)
))
)
until the display looks like this:
!"#$"%# &'()#) "
=1.&#F" (.#A)' )%-
Press
#
##
#
, the display will look something like this:
F"(.#55 3#A.>% +.
?+"()#! ""+### ##X
Enter the zone number
...
......
...
or use the
)
))
)
key to search, the display will look something like this:
F"(.#53 5#A.>% +.
T"%(L.# !.).>) "+#X
!
Pressing
&
will make the zone chime every time
it is activated (an Arrow will appear to the right of the
zone number), to clear the chime, press
&
again.
Pressing
%
will display the zone text.
Every time the selected zone is activated, its status will be
displayed and the keypad will chime (if selected), the
display will also look something like this:
F"(.#53 5X*>)1 R.
T"%(L.# !.).>) "+#X
F"(.#53 5XA.>% +.
T"%(L.# !.).>) "+#X
Press
#
##
#
when finished, the display should look like this:
!"#$"%# &'()#) "
=1.&#F" (.#A)' )%-
Press
(
((
(
to exit the menu and return to normal.