Log Event Description
PROG. START An Engineer code has been entered
PROG. END The Engineer has logged out of the Programming menu
BOX LID The control panel lid has been removed causing a Tamper alarm
BELL #,# Tamper A Bell Tamper input from device #,# has been activated
AUX #,# Tamper An Auxiliary Tamper input from device #,# has been activated
EXP #,# Tamper The cover of expander #,# has been removed
RKP #,# Tamper The cover of keypad #,# has been removed
RKP #,# LOST Keypad ## has been lost from the network
EXP #,# LOST Expander ## has been lost from the network
FIRE ### Active Zone ### (programmed as Fire Alarm) has caused an alarm
Zone ### Tamper Zone ### has caused a Tamper alarm
Zone ### Active Zone ### has been activated
Zone ### Restore Zone ### has restored to its normal condition
Zone ### Omitted Zone ### has been omitted
Zone ### Un-Omit Zone ### has been reinstated
Zone ### Test Start Zone ### has been put on test
Zone ### Test End Zone ### has been removed from test
RKP LOCKED #,# Keypad #,# has been locked out from too many invalid key presses
CODE #,# Too many invalid key presses have caused a tamper alarm from keypad #,#
TEST FAIL ###) Zone ### has failed its Soak test
MANUAL TEST CALL A manual test transmission has been initiated
AUTO TEST CALL An Automatic test transmission has been initiated
WALK The Walk Test mode has been initiated
TESTED ### Zone ### has been tested
DEFAULTS LOADED The factory default values have been loaded into memory
FIRST KNOCK ### Zone ### (which is programmed as double knock) has activated for the first time
CURRUPT EVENT No event has been stored in memory
Event Log Hotkeys
When viewing the system log there are 8 hotkeys available.
These hotkeys allow certain events to be found easier
without the need for searching.
The following hotkeys are available:
!
= Priority Alarms (PA, Fire etc.)
0
= Normal Alarms (Guard, 24hr, Entry/Exit etc.)
*
= Opens and Closings (Arm, Disarm etc.)
+
= Omits and Reinstates (Zone Omits etc.)
4
= Maintenance (System Tests, Engineer Program etc.)
,
= Tampers (Zone, Bell, Aux etc.)
-
= Test Calls (Communicator Active, successful etc.)
&
= Next Matching Event (On Screen Event)
!
The CHIME key will jump straight to an event that
matches the one that is displayed on the screen i.e.
if Code 01 is displayed, pressing CHIME will find
any preceding event that relates to a User code
being entered.