EasyManua.ls Logo

Texecom Premier 888 - User Options

Texecom Premier 888
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Th
e
U
ser
M
enu
P
rem
i
er
888
&
8168
U
ser
M
anua
l
32 INS177
User Options
This menu will only be displayed if the Custom User type is
selected (see page 31 for details).
This option defines which functions the selected user can
access when their code is entered.
The following options are available:
1 - Arming
Yes: Areas assigned to the selected user can be armed.
No: Areas assigned to the selected user cannot be armed.
2 - Disarming
Yes: Areas assigned to the selected user can be
disarmed.
No: Areas assigned to the selected user cannot be
disarmed.
3 - Omitting
Yes: Zones assigned to the same areas as the selected
user can be omitted, providing that they have the
omit’ attribute assigned to them.
No: Zones assigned to the same areas as the selected
user cannot be omitted.
4 - Eng. Reset (Engineers only)
Yes: Areas assigned to the selected user can be Engineer
reset after an Alarm has occurred.
No: Areas assigned to the selected user cannot be
Engineer reset after an Alarm has occurred.
5 - Local Arming
Yes: Areas assigned to the selected user can only be
armed from a keypad assigned to the same areas.
No: Areas assigned to the selected user can be armed
from any keypad on the system.
6 - Local Disarm
Yes: Areas assigned to the selected user can only be
disarmed from a keypad assigned to the same areas.
No: Areas assigned to the selected user can be disarmed
from any keypad on the system.
7 - Silent Arm
Yes: Areas assigned to the selected user can be armed
silently (see page 10 for details).
No: Areas assigned to the selected user cannot be armed
silently.
8 - Disarm First
Yes: If areas are already armed and the selected user
enters their code, the ‘Disarm’ option is displayed.
No: If areas are already armed and the selected user
enters their code, the Arm’ option is displayed.
9 - User Menu
Yes: The selected user has access to the User menu.
However, the selected user will only have access to
options assigned in User Config.’ (see page 33 for
details).
No: The selected user will not have access to any of the
options in User Config.’
10 - Eng. Program (Engineers only)
Yes: The selected user can access the Engineer
Programming mode. This option should NEVER be
enabled for normal users, as it will allow the
programming of the system to be altered to such a
degree that the system may fail to operate.
No: The selected user cannot access the Engineer
Programming menu.
11 - Dual Code
Yes: The selected user can only access an area when a
second User code (with theDual Code attribute and
also assigned to the same area) is entered. Dual
Code users will also activate the ‘1
st
and 2
nd
Code
output type.
No: The selected user will operate as normal.
12 - Vacation
Yes: The selected user is enabled the first time it is used to
disarm the system and can be used as many times as
required. However, it will be automatically deleted the
first time that the User 01 code is used to disarm.
Vacation users will only be deleted by the Master user,
once they have been used on the system.
No: The selected user will operate as normal.
13 - Door Strike
Yes: The selected user will activate any outputs
programmed as ‘Door Strike’, whenever their codes
are entered.
No: The selected user will not activate any outputs
programmed asDoor Strike’.
14 - Call Rem. PC
Yes: The selected user has access to the ‘Call Remote PC’
option, allowing them to initiate a call to a remote
upload/download PC (see page 35 for details).
No: The selected user does not have access to the ‘Call’
Remote PC’ option.
15 - Duress Code
Yes: The selected user will activate any outputs
programmed asDuress’, whenever their codes are
entered.
No: The selected user will not activate any outputs
programmed as ‘Duress
16 - Open/Close
Yes: The selected user will report open (disarm) and close
(arm) events to an Alarm Receiving Centre every time
they arm or disarm.
No: The selected user will report open (disarm) and close
(arm) events to an Alarm Receiving Centre.

Table of Contents