Premier Elite 8XP-W & 32XP-W Installation Manual
14 INS467-4
6. Programming
It is highly recommended that you upgrade the Panel Firmware to the latest version to ensure full
compatibility; however the system is backwards compatible as detailed in the table on page 5.
It is not possible to upgrade Premier panels to Premier Elite firmware.
Premier EliteV2.xx 24/48/88/168 & 640 + Ricochet™ MT2
Option Switches
In this mode only option switch 3 should be on.
Introduction
The firmware upgrade now requires that Ricochet™ devices are learned through the Zone Setup
Menu, and Premier Elite SmartKey™ are learned through the User Setup menu, the "Configure
Radio" menu in Engineer's Utilities is now redundant and should not be used.
Learning Devices
To learn a device to a Zone select the Zone from the Zone Setup Menu, Zones that are capable of
having a Ricochet™ device learnt to them will be displayed as follows:-
Fig 1
Fig 1indicates the pre-assigned zone number, the expander being used and the device slot on the
expander.
Once a device has been learnt the display will be as Fig 2:-
Fig 2
If you are unsure if a zone already has a device learned to it, you can go to the menu as in Fig 1,
press and then if a device is already learnt the display will look like Fig 2, if not then it will
look like Fig 3
Fig 3
Please see the diagram on the next page to learn devices.
Deleting Devices
To delete devices from the expander is the same as learning them; choose the zone you wish to
delete, and follow the procedure to learn the device, when the screen shows “Learning” press .