Premier Elite 8XP-W & 32XP-W Installation Manual
24 INS467-4
Removing Detectors
If a detector is no longer required it must be unassigned from the system. To remove a detector from
a zone, proceed as follows:
1. Select engineer’s mode by entering the engineer code followed by / then .
2. Enter  to select the All Zone Options menu.
3. Enter the two digit zone number that you want to remove the detector from e.g., .
4. Enter  to program the zone type as Null. The panel will generate an acceptance tone
and the detector is no longer assigned to the selected zone.
Learning SmartKey™
All SmartKey™ must be assigned to one of the available users on the system. The users available
will vary depending on the control panel:
Control Panel Available Users
Premier 412 Users 1 to 31
Premier 816 Users 1 to 31
Premier 832 Users 1 to 63
 
  
  
  

Ent er Zone
Number

  

Enter Engineers code
Then press then
/

Accept ance Tone
from Panel
