1. Pink = Power Up or Down
2. Green = Successful communication with
the system
3. Flashing Blue = communication with
system.
4. Red = Out of Range
5. Turquoise = Function Mode
on Premier 412 816 & 832 Function 1 is the Arm Button and Function 2 is the Disarm button.
PA Activation
By default PA activation is enabled on the SmartKey™, however the control panel should be
programmed to enable Radio PA. Please refer to your Control Panel manual for details.
Enable/Disable Alarm Status LED’s
The Alarm Status LED’s can be enabled or disabled either from the Engineers Keypad see page 35,
or RICOCHET™ Monitor.
Alarm Status LED’s are not available on the Legacy Premier 412, 816 & 832. For legacy Premier 24/48/88/168 &
640 please see page 21 to programme the output functions required to enable the LED indications.
Auxiliary Functions
The SmartKey™ can also be used to activate auxiliary devices from the control panel outputs. The
function keys should first be enabled either from the Engineers Keypad see page 35, or
RICOCHET™ Monitor. Once enabled the user can enter Auxiliary mode by pressing the power
button when the SmartKey™ is powered up, the status LED will change from blue to turquoise to
indicate Function mode.
Once enabled the outputs should be programmed in the control panel to activate the desired
function. Please refer to the Control Panel manual for details on how to programme the outputs.