10. Specifications
Electrical
Operating Voltage 10 - 13.7VDC
Current Consumption <120mA
Network
4-wire standard 7/0.2 alarm cable up to 250m. Star, Daisy Chain or
any combination.
Outputs 1 - 8 Not Used
Operating Temperature
-10°C (+14°F) to +50°C (+122°F)
Storage Temperature
-20°C (-4°F) to +60°C (+140°F)
Maximum Humidity 95% non-condensing
EMC Environment
Residential, Commercial, Light Industrial
or Industrial
Physical
Dimensions 170mm H x 140mm W x 35mm D
Packed Weight 500gms
Wireless
Frequency 868.0Mhz 868.6Mhz or 433.05Mhz 434.79Mhz
Please refer to product label to determine frequency
Receiver Category 1 Class 2
Receiver LBT (Listen
Before Talk)
Yes
Transmitter Duty Cycle
433Mhz <10%
868Mhz <1%
Standards
2004/108/EC (CE directive): Hereby, Texecom declares that this device is in compliance
with the essential requirements and other relevant provisions of Directive 2004/108/EC.
Weee Directive: 2002/96/EC (WEEE directive): Products marked with this symbol cannot
be disposed of as unsorted municipal waste in the European Union. For proper recycling,
return this product to your local supplier upon the purchase of equivalent new equipment,
or dispose of it at designated collection points. For more information see:
www.recyclethis.info.
RoHs Directive: 2002/95/EC RoHS Compliant. Hereby, Texecom declares that this device does not contain lead,
mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated depheny ethers
(PBDE) in more than the percentage specified by EU directive 2002/95/EC, except exemptions stated in EU
directive 2002/95/EC annex.
This product is a Type B Moveable device and is suitable for use in systems designed to comply with EN 50131-
1, EN50131-3, EN50131-5-3 and PD6662 at Grade 2 and Environmental Class II.