If the Limited Alarm Restarts feature is enabled, the following additional
alarm codes may only be cleared from the Guarded Access Menu. If this is
the case, the CLEAR soft key will not appear if the alarms are displayed from
the Main Menu or the Maintenance Menu.
Alarm Code 23 Cooling Cycle Fault
Alarm Code 24 Heating Cycle Fault
Alarm Code 32 Refrigeration Capacity Low
Alarm Code 82 Compressor Temperature Shutdown
Alarm Code 93 Low Compressor Suction Pressure
If the Limited Alarm Restarts II feature is enabled, the following additional
alarm codes may only be cleared from the Guarded Access Menu. If this is
the case, the CLEAR soft key will not appear if the alarms are displayed from
the Main Menu or the Maintenance Menu.
Alarm Code 18 High Engine Coolant Temperature
Displaying and Clearing Alarm Codes
Alarms are displayed and cleared using the Alarm Menu. From the Standard
Display, press the MENU key.
Figure 64. Menu Key
The Language Menu or Alarms Menu will appear. If the Language Menu
appears, press the NEXT key to show the Alarm Menu. When the Alarm
Menu is shown, press the SELECT key.
OOppeerraattiinngg IInnssttrruuccttiioonnss ffoorr PPrreemmiiuumm HHMMII CCoonnttrrooll PPaanneell

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King T-1090 SPECTRUM and is the answer not in the manual?

Thermo King T-1090 SPECTRUM Specifications

General IconGeneral
BrandThermo King
ModelT-1090 SPECTRUM
CategoryRefrigerator
LanguageEnglish

Related product manuals