Auto Switch from Diesel to Electric Report alarm at end of the day.
118 Auto Switch from Electric to Diesel Auto Switch from Diesel to Electric
127 Setpoint Not Entered Be sure the setpoint is set to the
required Temperature.
128 Engine Run Time Maintenance
Reminder #1
Report alarm at end of the day.
129 Engine Run Time Maintenance
Reminder #2
Report alarm at end of the day.
130 Electric Run Time Maintenance
Reminder #1
Report alarm at end of the day.
131 Electric Run Time Maintenance
Reminder #2
Report alarm at end of the day.
132 Total Unit Run Time Maintenance
Reminder #1
Report alarm at end of the day.
133 Total Unit Run Time Maintenance
Reminder #2
Report alarm at end of the day.
134 Controller Power On Hours Report alarm at end of the day.
145 Loss of Controller ON Feedback Signal If unit is shut down repair immediately.
Otherwise, report alarm at end of the
day.
165 Low Engine Power Available Report alarm at end of the day.
Datalogger Menu
The unit can be equipped with an optional DAS Data Logger if desired.
A Start of Trip marker can be sent to the unit ServiceWatch Data Logger and
the optional DAS Data Logger (if equipped).
If equipped with the optional DAS Data Logger, the most recent DAS trip
record can be printed. The most recent trip is defined as the trip following
the last Start of Trip marker sent to the data logger.
The ServiceWatch Data Logger and DAS Data Logger (if equipped) are
accessed using the Data Logger Menu. From the Standard Display, press the
MENU key.