EasyManua.ls Logo

Thermo King VM-405 PBBD2 - Sealing Holes

Thermo King VM-405 PBBD2
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
TK 56430-18-IP-EN
Sealing Holes
Proper sealing of all holes drilled into the cargo box is very important. Air leaks will greatly affect the performance of
the unit and water leakage can damage or ruin the cargo.
All component mounting holes and access holes for electrical and refrigerant hoses must be sealed both inside and
outside the cargo box.
Sealing Methods
Any of the following sealing methods are acceptable:
Silicone Sealant (neutral/alcohol cure, exterior grade, flexible, non-hardening)
Strips of foam rubber material applied between surfaces (closed cell foam only)
Molded gaskets (for specific applications)
Expandable Spray Foam (for larger holes)
Plumbers putty
All unit mounting holes must be sealed both inside and outside the cargo box.
SSeeccttiioonn 44 -- UUnniitt IInnssttaallllaattiioonn SSttaannddaarrddss aanndd PPrroocceedduurreess

Table of Contents

Other manuals for Thermo King VM-405 PBBD2

Related product manuals