3. Wiring
1.
How to wire
3-5
TSC
1-2-2
Connection of FG wire
Production of FG cable example (prepare it by yourself)
Recommended electric wire: 1.25 mm
2
(AWG16)
Connect the FG wire to the GND terminal, and ground it to the earth.
1-2-3
Wiring diagram
Use one machine of TSC (no reset switch)
The motor is energized as soon as the emergency stop switch is released.
Connecting TDO will open the internal relay K1, and the TDO emergency stop switch is
activated.
While TDO is not connected, the internal relay K1 is closed.
When connecting TSC to the network unit TNU, do not wire the CN5 pin number
(S1).
(Doing so may cause fault.)
FG wire
GND terminal
Control
power
supply
24V
0V
S1
S2
MPO
MPI
24V
0V
EMG-
TDO
0V
Motor
power
supply
X
Emergency
stop switch
CN4
CN3
K1
TSC
(M3 cross-recessed pan-head screws)