EasyManua.ls Logo

THK TSC Series - Page 32

Default Icon
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. Wiring
1.
How to wire
3-9
TSC
Solo emergency stop of TSC (TDO uses)
One emergency stop switch can stop all the TSCs urgently.
When TDO is connected to any TSC, the emergency stop by TDO stops only the TSC
urgently.
Use the external relay CR with the surge absorption diode at 0.1 A or less coil current.
When connecting TSC to the network unit TNU, do not wire the CN5 pin number
(S1).
(Doing so may cause fault.)
24V
S1
S2
24V
0V
EMG-
0V
Emergency
stop switch
CN4
CN3
K1
TSC
MPO
MPI
CN4
X
TDO
0V
S1
S2
24V
0V
EMG-
0V
CN4
CN3
K1
TSC
MPO
MPI
CN4
X
CR
CR
TDO

Table of Contents