parameter.
By setting *pbo != IS_CAPTURE_STATUS before calling the function, pbo
contains the following digitizing status:
IS_VIDEO_NOT_FINISH = Digitizing of the image is not completed yet.
IS_VIDEO_FINISH = Digitizing of the image is completed.
By setting *pbo == IS_CAPTURE_STATUS before calling the function, pbo
contains the following digitizing status:
IS_VIDEO_NOT_FINISH = Digitizing of the image is not completed yet.
IS_VIDEO_FINISH = Digitizing of the image is completed.
IS_CAPTURE_STATUS = Transfer error or conversion problem (e.g.
destination memory is invalid)
The parameter IS_CAPTURE_STATUS replaces the previous parameter
IS_TRANSFER_FAILED.
The parameter IS_TRANSFER_FAILED was moved into the new header file
uc480_deprecated.h, which contains all obsolete function definitions and
constants. If necessary the header file uc480_deprecated.h can be included
in addition to the header file uc480.h.
One of the submitted parameters is outside the valid
range or is not supported for this sensor or is not
available in this mode.