2-15
Chapter 2
NOMENCLATURE AND FUNCTIONS
17. Control output terminals
These terminals permit the VX-3000 system to
control other connected external equipment.
• Control output terminals 1 – 5
Relay contact outputs (Form A contacts)
Withstand voltage: 30 V DC
Allowable current: 1 A
• Control output terminals 6 – 10
Open collector outputs (polarized)
Withstand voltage: 30 V DC
Allowable current: 100 mA
Note
The "C" terminals of the Control output terminals
6 through 10 are interconnected.
18. DC Power input terminals
Power is supplied to this terminal from the VX-
3000DS or VX-3150DS Power supply manager or
the AD-246 AC Adapter.
19. LINK/ACT indicators
Indicates the connection status of the LAN
connection terminal.
Lights or ashes when the connection is correct.
Remains unlit when no connection is established.
20. LAN link connectors
Connect the VX-3000 system components or
switching hubs. (See p. 3-83 "VX-3000 Unit's
LAN Link Connector Connection.")