MAINTENANCE AND TUNE-UP PROCEDURE
This section describes the servicing procedures for each item in the Periodic Maintenance requirements.
API Classifi cation SF – SG (SAE 15W – 40)
It is important to inspect the engine oil before each period of operation. The engine oil should be changed every
• Place unit on fl at surface.
• Remove dipstick and wipe off with a clean cloth.
• Return the dipstick to the hole. Push the dipstick in until the threads prevent it from going any farther.
Do Not screw the dipstick into place while attempting to check the oil. Doing so will cause a false
• Check oil level to see if it is between min and max indicators.
• Add oil as necessary to reach the required level.
- Return the dipstick to its original position. Be sure to tighten the cap into place after checking the oil.
• Run unit for at least 5 minutes or until warm, shut off.
• Place suitable container for draining oil beneath engine.
- Container should be capable of holding at least 1 gallon.
- Warning - Engine components may be hot. Use caution while attempting to change the oil.
• Remove the engine drain plug, oil fi lter cap, spring, and oil fi lter screen. Drain the oil completely.
• Check condition of O-ring and fi lter screen for foreign material before re-installing.
• Install the drain plug and torque to 12 ft. / lbs.
• Fill with 25 to 31 oz. of API classifi cation SF – SG (SAE 15W – 40) oil.
• Start engine and check for leaks.